Blowing more insulation into an attic looks like a simple, low-risk upgrade. NRCan's Keeping the Heat In treats fire safety as a serious concern in the same job, because insulation is piled around the things in an attic that get hot: recessed light fixtures, chimneys and old wiring.

Pot lights

NRCan says standard recessed fixtures are hard to air seal and can become a fire hazard when covered with insulation. It advises replacing them with approved airtight fixtures or covers. Where a box is built around a fixture, NRCan gives a size of 800 cm³ per watt of fixture, with at least 12.5 mm (1/2 in.) clearance at the sides and top. LED flush-mount fixtures are an alternative. The safe course is to identify every recessed light from below before the insulation crew arrives, and agree in writing how each will be handled.

Masonry chimneys

NRCan advises not to insulate a suspect chimney. Gaps between the chimney and the framing should be sealed with sheet metal flashing and non-combustible sealant, not foam or ordinary caulk. A barrier is built 75 mm (3 in.) from the masonry face and at least 75 mm above the insulation, so that loose insulation cannot fall against the chimney. A cracked or deteriorated chimney is a job for a chimney professional before the attic work, not after.

Metal chimneys and flues

For metal chimneys, NRCan says to keep insulation at least 75 mm (3 in.) away using a non-flammable radiation shield, and to clamp the storm collar without sealant. The manufacturer's listed clearances for the chimney also apply, and they can be larger. Expanding foam around a metal chimney is the kind of shortcut that creates the hazard the insulation work was never meant to add.

Wiring

NRCan says to turn off power before working in the attic, to consult an electrical contractor about questionable wiring or corroded connections, and to replace damaged or frayed wiring before insulating. Once the attic is full of insulation, wiring problems are hidden and much harder to reach. Older homes may have wiring that an electrician should look at first; that assessment belongs before the insulation contract is signed.

Foam and other materials

In accessible areas such as knee wall spaces, NRCan notes that exposed foam must be fire protected. Air sealing around heat sources calls for the materials NRCan names for that use, including high-temperature sealants at flues and where a chimney meets framing. Before disturbing existing insulation, check for vermiculite, which may contain asbestos; see our article on vermiculite insulation.

Need a pro for this?

What next?

References

  1. Natural Resources Canada. Keeping the Heat In - Section 5: Roofs and attics, Web page, 5.1.2 fire safety: pot lights, masonry and metal chimneys, wiring; 5.3 knee walls (fire protection of foam). Accessed 2026-11-03.

General information based on the official sources listed above, not legal, tax or engineering advice. Rules change; check the source or ask a qualified professional before you act.

Seen this on site?

Ask other builders how they handle it, or share what worked for you.

Discuss in Community