ArtBuild OS
← Common failures

Site Safety · Easy

Power tools and hearing loss: Canada's 85 dBA limits and what to do about them

In short: CCOHS lists a circular saw at about 115 dB(A) at 1 metre; most provinces limit 8-hour exposure to 85 dB(A) with a 3 dB exchange rate. Controls first, then hearing protection.

Nov 4, 2026

Before you start: check these

0 of 6 done

Hearing loss from construction does not hurt and does not show up for years. By the time a worker notices ringing ears or trouble following a conversation, the damage is permanent. CCOHS's noise fact sheets give the numbers that explain why ordinary renovation tools are a real hearing hazard.

How loud the tools are

CCOHS's table of typical noise levels lists a pneumatic chipper and a hand-held circular saw at about 115 dB(A) at 1 metre, a chainsaw or leaf blower at 106 to 115, and a power lawn mower at 92. Shouted conversation is around 90 to 95. On a renovation site, demolition hammers, saws, grinders and compressors often run at the same time, in rooms with hard surfaces that reflect sound.

The legal limits

CCOHS's summary of occupational exposure limits shows that British Columbia, Alberta, Saskatchewan, Manitoba, Ontario, Quebec, New Brunswick, Nova Scotia, Prince Edward Island, Newfoundland and Labrador and Yukon set a maximum of 85 dB(A) for 8 hours, with a 3 dB exchange rate; the federal limit is 87 dB(A). The Northwest Territories and Nunavut also use 85 dB(A). Some jurisdictions also set a peak limit of 140 dB for impulse noise. Several reference the ACGIH values rather than stating a number.

What the exchange rate means

CCOHS explains that a 3 dB increase doubles the sound energy. With a 3 dB exchange rate, every 3 dB above 85 halves the allowed time: 88 dB(A) for 4 hours, 91 for 2 hours, and so on. At the 115 dB(A) of a circular saw at arm's length, the allowed unprotected time is measured in seconds, which is why even short cuts add up over a day.

Signs of a noise problem

CCOHS suggests simple questions: do people have to raise their voices to talk at work, and do they have ringing in their ears after a shift? Yes answers suggest a noise problem, and a noise assessment can then identify sources, levels, who is exposed and for how long. In some jurisdictions, above 85 dB(A) or a level of 90 dB(A) at any time, employers must provide hearing protection, train workers and arrange hearing tests.

Controls first, then protection

CCOHS calls engineering changes to the noise source or the workplace the best way to reduce noise, with ear muffs or plugs used where technology cannot control the problem, as an interim measure. On renovations that means quieter tools and blades where available, cutting outside or in a separate area, keeping compressors away from the work, and limiting who is in the room. Hearing protection still belongs on every site for the work that stays loud. Check your provincial OHS regulation for the exact duties.

What next?

References

  1. Canadian Centre for Occupational Health and Safety. Noise - Occupational Exposure Limits in Canada, Web page, Table of limits by jurisdiction and notes. Accessed 2026-11-04.
  2. Canadian Centre for Occupational Health and Safety. Noise - Basic Information, Web page, Typical noise levels (Table 2), 3 dB doubling, signs, controls, hearing protection. Accessed 2026-11-04.

General information based on the official sources listed above, not legal, tax or engineering advice. Rules change; check the source or ask a qualified professional before you act.

Seen this on site?

Ask other builders how they handle it, or share what worked for you.

Discuss in Community