Condensation after an energy retrofit: humidity limits, ventilation and combustion air

In short: A tighter house holds more moisture. NRCan's table of maximum indoor humidity by outdoor temperature and glazing, the warning signs, and how to add ventilation safely.

Nov 4, 2026

Before you start: check these

0 of 6 done

A common complaint after a retrofit is water streaming down new windows, musty closets or mould on an outside wall. The retrofit worked: the house leaks less air. What was missing was a plan for the moisture and the combustion air that the old leaks used to handle.

Why it happens

NRCan says most Canadian homes have excess air leakage, and that about 25 percent of heat loss can come from it. Seal those leaks and the water vapour from cooking, showers and people stays inside. NRCan's target is to change the total household air at least once every three hours, with separate combustion air for fuel-burning appliances. Its list of houses prone to indoor air problems includes homes that were air sealed without adequate ventilation, homes with non-ducted range hoods or weak bathroom fans, and homes with fireplaces or strong exhaust fans competing for air.

Signs to watch for

NRCan lists excessive condensation on double-glazed windows, staining or mould in bathrooms, closets and on exterior walls, stuffy or musty air and lingering odours, back-puffing from heating or water heating equipment, and backdrafting from fireplaces. Occasional condensation is normal; frost or heavy condensation means moisture should be reduced or ventilation increased.

How much humidity the windows can take

NRCan's Table 9-1 gives the maximum indoor relative humidity at 21°C before windows condense. At -20°C outside, for example, it is 34 percent for ordinary double glazing, 50 percent for double-glazed low-E and 67 percent for triple-glazed low-E; at -30°C the figures fall to 25, 42 and 60 percent. A hygrometer and the windows themselves are the simplest gauges. Better windows tolerate more humidity, which is one reason condensation can move to the remaining older windows after a partial replacement.

Reduce moisture, then ventilate

NRCan's first steps are to cut moisture sources: no firewood stored indoors, no indoor laundry drying, dryers vented outdoors, humidifiers disconnected, exposed earth in basements and crawl spaces covered, leaks fixed and grading and eavestroughs working. Run kitchen and bathroom fans when in use, on timers or humidity controls, choosing quiet ENERGY STAR fans that vent fully outdoors. A contractor can add a damper-controlled fresh-air duct to the furnace return at least 3 m from the furnace. NRCan prefers a heat recovery ventilator, which typically recovers 70 to 80 percent of the heat, or an energy recovery ventilator in very dry climates, and says these must be installed, balanced and commissioned by a certified technician.

Do not starve the appliances

Exhaust fans that run without matching supply air lower house pressure. NRCan warns that insufficient supply air can backdraft combustion gases. Signs include soot near appliances, melted plastic fittings on water heaters, odours, hard-to-start fireplace fires, headaches or nausea and nuisance CO alarms. Solutions include direct-vent or sealed-combustion equipment or heat pump systems, and CO detectors in homes with combustion appliances or an attached garage.

Need a pro for this?